SETUP
Mount Stepper module to the BUG-O tractor using two (2) ¼-20 x screws, hex head, socket head or
cap screws (not supplied), using the mounting holes on the BUG-O carriage.
Mount Limit Switch to work where a trip mechanism will actuate the limit switch with each revolution of
the work piece. “Trip” can be a screw head, ag, spot weld or any other item that will activate the limit
switch / BUG-O. Mounting brackets used to install the Limit Switch are of your own make or purchase
that is appropriate to the specic application.
Plug power cord of Stepper Module into main power supply.
BUG-9875 STEPPER MODULE SWITCH ASSEMBLY / PARTS LIST / WIRING DIAGRAM
PART NO. QTY DESCRIPTION
900-4-001 96" Power Cord, SJO 18/2-250,
300V
BUG-1417 1 Cross Roller Plunger Actuated
BUG-9217-P 1 Cord Grip
BUG-9857 1 Cable Connector, 2-7, M