Bug-o-systems Speed Weaver II Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
8
1. The Speed Control Knob (A) sets the traverse speed of the cross rails:
turn clockwise to increase speed. Common weaving speeds are from
“20” to “30” on the graduated dial.
2. Two Dwell Control Knobs (B, C) set the time interval that the torch
dwells at each end of the stroke - one control for each side. Dwell time can
be set from 0 to 3 seconder independently for left and right side of weave.
3. The Amplitude Control Knob (D) on the side of the machine sets the
length of the weave stroke between .125 and 2" (3 to 51 mm). The dial counter
reads 100 for every .125" (3 mm) of stroke, eg. a reading of 0300 would give
a .375" (9.5 mm) weave. The dial counter has a lever on the bottom that locks
the amplitude setting.
4. Power Controls.
Toggle Switch (E) is used to turn power ON and OFF to the machine.
Circuit Breaker (F) is rated at 0.7A (.5A for 240V) and provides protection
against overloads. If it pops up it can be reset by pushing down.
CAUTION: Find and correct the cause of overload before resetting.
5. Weld Contact Controls.
Toggle Switch (G) turns the Weld contacts ON when momentarily
pushed forward and released, and turns them OFF when pushed back.
The Weld Contacts are wired into the terminals on the “Amphenol”
Connector (H); the leads from the trigger switch on the welding gun should
be connected to the mating connector provided.
NOTE: The Weld Contacts will also shut off if the power to the Weaver is
interrupted or turned off for any reason.
FUNCTION AND CONTROLS
D
A
F
E
H
G
J
B, C
13
ELECTRICAL COMPONENT CHART
TROUBLESHOOTING GUIDE
120 VAC 240 VAC 42 VAC
BUG-5300 BUG-5302 BUG-5304
VT Volt Trap BUG-1393 BUG-1563 BUG-1393
PC Power Cord BUG-9445 GOF-3115 BUG-9445
CB Circuit Breaker CIR-5247 BUG-2952 BUG-2933
PO Power Socket BUG-5321 BUG-9595 BUG-5321
T Transformer BUG-5001 BUG-5002 BUG-5003
MCB Motor Control Board BUG-1770
TCB Tractor Switch BUG-5333
WCB Weaver Circuit Board BUG-5335
SW1 Power ON-OFF Switch ARM-2279
WT Connector-Weld Contact BUG-9486
SW2 Toggle Sw.-Weld Cont. BUG-5323
SW3 Rotary Sw.-Mode Select BUG-1548
Pl Speed Pot., 1 OK BUG-9686
P2,P3 Dwell Pot. L&R BUG-5054
SN Sensor Assy. L&R BUG-5385
M Gear Motor BUG-1600
ITEM
DESCRIPTION
FUNCTION
PART NUMBER
PROBLEM CAUSE REMEDY
Machine dead. No Power. Check supply line for power
Plug power cord in rmly.
Circuit-breaker Find cause of overload
popped. correct and reset breaker.
Weaver runs, Bad tractor switch. Replace tractor switch BUG-5333
tractor dead. (plug in on Weaver board).
Weaver does not Faulty speed board. Replace speed board BUG-1770.
stop in dwell.